Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Acta odontol. latinoam ; 35(1): 10-15, Apr. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383419

ABSTRACT

ABSTRACT The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88); [SDR] t0: 27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.


RESUMEN El objetivo del presente estudio fue determinar la microdureza Vickers (HV) en resinas bulk-fill a diferentes profundidades. Se confeccionaron probetas semicilíndricas de 6 mm de diámetro y 4 mm de profundidad con diferentes composites de aplicación en bloque (Bulk-fill): Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] y Surefill (Dentsply) [SF]. Se polimerizaron con Coltolux LED (Coltene) con 1000 mW/cm2 durante 20s. La HV se determinó realizando 3 indentaciones con 300 g durante 8 s a 1,2 3 y 4 mm desde la superficie de la probeta hacia el interior inmediatamente después de curada y a las 24 h. Se utilizó un microdurómetro Vickers Future Tech FM300. Los resultados se analizaron estadísticamente mediante ANOVA de dos vías y Prueba de Tukey. La media y DS de HV fueron: [FBF] t0: 49,23(4,65) / 48,32(3,36) / 44,38(2,06) / 40,59(2,58); [FBF] t24: 61,37(3,47) / 62,63(3,03) / 57,27(5,22) / 56,37(5,88); [SDR] t0: 27,81(3,13) / 28,07(2,4) / 27,24(2,94) / 25,71(3,0); [SDR] t24: 35,11(2,16) / 35,17(1,96) / 35,53(1,81) / 33,18(2,08); [FU] t0: 41,43(1,41) / 39,87(0,88) / 38,11(1,81) / 39,09(1,92); [FU] t24: 49,27(1,54) / 48,77(1,77) / 48,65(1,88) / 46,76(4,93); [SF] t0: 71,35(7,09) / 67,39(9,76) / 68,95(6,21) / 64,1(8,35); [SF] t24: 76,06(6,61) / 75,31(9,37) / 75,2(11,57) / 69,81(12,14). La evaluación con análisis de varianza mostró el efecto significativo de las variables material, profundidad y momento del registro (p<0,05) y la prueba de Tukey mostró que los sitios de registro (profundidad) fueron estadísticamente significativos, dando cuatro grupos homogéneos. Bajo las condiciones de este estudio podemos concluir que la microdureza de las resinas de inserción en bloque se ve afectada por el nivel de profundidad y el tiempo pos curado.

2.
Acta odontol. latinoam ; 34(3): 221-225, 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383408

ABSTRACT

ABSTRACT The aim of this research was to determine compressive and shear bond strength of blocks prepared with bulk-fill and nanofill composite resin combinations. Materials used were Filtek Bulk Fill (FBF) and Z350 (both 3M-ESPE) and Surefil SDR flow (SFF) - Dentsply. To determine shear bond strength, cylindrical specimens 10 mm thick were prepared with composite consisting of thicknesses of 6 mm of one material and 4 mm of the other, in the following combinations: G1: FBF- FBF; G2: Z350-Z350, G3: FBF-Z350, G4: Z350-SFF and G5: SFFSFF. Materials were cured using a 1100 mw/cm2 light for 20 seconds for each layer. Samples were stored for 24 hours at 37 °C in distilled water and shear bond strength was determined. To assess compressive strength, cylindrical samples 4 mm diameter and 6 mm thick consisting of 4 mm + 2 mm were used in the same combinations as described above, stored in distilled water at 37 °C for 24 hours, after which compressive strength was determined. Both tests were performed with a Universal testing machine at a cross head speed of 1 mm/min. Results were analyzed with ANOVA and Tukey's test. Means and standard deviations in MPa for each group were the following: Shear bond strength: G1: 435.87 (65.86), G2: 233.6 (108.15), G3: 279.2 (22.05), G4:449.1 (109.35) and G5: 196.6 (51.16). Compressive strength: G1:160.07(4.27), G2: 149.49 (14.06), G3: 156.10 (29.99), G4: 199-30(39.28), G5: 171.23 (28.71). Evaluation with ANOVA showed no significant differences among combinations for compressive strength (p>0.05) and significant differences for bond strength (p<0.05). Tukey's test showed three homogeneous groups. Under these experimental conditions, it can be concluded that the study combinations have adequate mechanical behavior, equivalent to materials used individually. However, shear bond strength was affected by the combinations analyzed.


RESUMEN El objetivo de este trabajo fue determinar la resistencia compresiva (RC) y la resistencia adhesiva al corte (RAC) en bloques preparados con combinaciones de composites bulk-fill y nanoparticulados. Los materiales usados fueron Filtek Bulk Fill (FBF) y Z350 (ambos de 3M-ESPE) y Surefil SDR flow (SFF) - Dentsply. Para medir la RAC, se prepararon probetas cilindricas de 10 mm de espesor consistentes en 6 mm de un material y 4 mm del otro con las siguientes combinaciones: G1: FBF- FBF; G2: Z350-Z350, G3: FBF-Z350, G4: Z350-SFF y G5: SFF-SFF. Se curaron a 1100 mw/cm2 durante 20 segundos cada capa. Se conservaron 24 horas a 37 °C en agua destilada antes de determinar la RAC. Para medir la RC se prepararon probetas de 4 mm de diametro y 6 mm de espesor (4 mm + 2 mm de cada material), con las mismas combinaciones. Se conservaron en agua destilada a 37 °C durante 24 horas y se midió la RC. Ambos ensayos se realizaron con una máquina universal para ensayos mecánicos a 1 mm/min de velocidad de desplazamiento de cabezal. Los resultados se evaluaron con ANOVA y prueba de Tukey. Las medias y desviaciones estándar (MPa) para cada grupo fueron: RAC: G1: 435.87 (65.86), G2: 233.6 (108.15), G3: 279.2 (22.05), G4:449.1 (109.35) y G5: 196.6 (51.16). RC: G1:160.07(4.27), G2: 149.49 (14.06), G3: 156.10 (29.99), G4: 199-30(39.28), G5: 171.23 (28.71). ANOVA no mostró diferencias estadísticamente significativas para RC (p>0.05) y diferencias significativas para RAC (p<0.05). La prueba de Tukey mostró tres grupos homogéneos. En las condiciones experimentales de este trabajo puede concluirse que las combinaciones evaluadas tienen un comportamiento mecánico adecuado equivalente al de los materiales individuales. Sin embargo, la adhesión entre materiales se vio afectada por las combinaciones realizadas.

3.
Rev. Fac. Odontol. (B.Aires) ; 35(81): 51-56, 2020. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-1222848

ABSTRACT

El objetivo de este estudio fue comparar la radiopacidad de distintos materiales utilizados como sustitutos de la dentina según norma ISO 6876. Se utilizaron Biodentine-Septodont (a base de silicato de calcio), Equia Forte ­ GC Corporation (ionómero vítreo convencional), Sure Fill SDR Flow ­ Dentsply Sirona (composite bulk-fill), MTA Densell Reparative - Densell (a base de silicato de calcio). Se confeccionaron 12 probetas cilíndricas, tres por cada material, siguiendo las instrucciones de los respectivos fabricantes y se colocaron en estufa a 37°C durante su fraguado. Se tomaron radiografías oclusales digitales junto a una cuña de aluminio graduada según norma ISO 6876. En cada imagen se determinaron los valores de L de la escala CieLab (negro-blanco) con el programa Photoshop (Adobe). Los resultados se analizaron estadísticamente mediante ANOVA y prueba de Tukey (AU)


Subject(s)
Calcarea Silicata , Composite Resins , Chemical Phenomena , Dentin , Glass Ionomer Cements , Materials Testing , Analysis of Variance
4.
Acta odontol. latinoam ; 32(3): 126-132, Dec. 2019. graf
Article in English | LILACS | ID: biblio-1130718

ABSTRACT

ABSTRACT The aim of this study was to evaluate the effect of flowable composite or glass ionomer liners on the shrinkage stress of a restorative composite resin. Fifteen previously sandblasted metal boxes were attached to a universal mechanical testing machine (INSTRON 1011, Instron Corporation). Five of these boxes were filled with Filtek Z350 XT (FXT) Universal Restorative A2 (3M ESPE) (Group 1 or Control). Two further groups of 5 boxes were prepared by interposing a layer of Vitrebond Light Cure Glass Ionomer 3M ESPE (VGI) (Group 2 or G.I.) or Filtek Z350 XT Flowable Restorative A2 3M ESPE (FFR) (Group 3 or Flowable) between the box and the composite resin, completing with the same volume of composite as in Group 1. Upon activating lightcuring, the filled boxes mounted on the testing machine were videoed for 60 seconds (40 s photoactivation and 20 s postcuring), timed with a digital chronometer. Force values were recorded in newtons and converted into stress according to contact surface. Stress values were recorded every 10 s. Results were analyzed using repeated measures ANOVA. Mean and standard deviation in kPa (stress) recorded for each group were: Control group: 126.2 (30.8); G.I.: 48.4 (18); Flowable: 27.9 (19.5). Statistical analysis showed significant differences between the control group and the rest (p<0.01), with no significant difference between groups with glass ionomer liners and flowable resin liners (G.I. and Flowable). Under the experimental conditions of this study, it can be concluded that polymerization shrinkage stress can be reduced by the presence of a liner between the preparation and the restorative material.


RESUMEN El objetivo de este trabajo fue evaluar el efecto de la colocación de una capa de Composite flow o Ionómero vítreo sobre la tensión de contracción de un composite para restauración. Se utilizaron 15 cajas metálicas previamente arenadas y conectadas a la máquina universal para ensayos mecánicos (INSTRON 1011, Instron Corporation). Cinco de estas cajas (G1) se rellenaron con Filtek Z350 XT (FXT) Universal Restorative A2 3M ESPE. Al iniciar la activación de la unidad de curado se comenzaba a registrar con una cámara de video y un cronómetro digital desde el comienzo de la activación de la lámpara hasta 60 s después, registrando los valores post curado durante 20 s. Los valores de fuerza generados por la polimerización fueron registrados en newton de cada 10 s para los 15 ensayos. Los valores fueron convertidos en tensión de contracción según la superficie de contacto. Se realizaron además dos grupos de cajas (5 en cada una) en los cuales se colocaron una capa inicial de Vitrebond Light Cure Glass Ionomer 3M ESPE (VGI) (G2 o IV) y Filtek Z350 XT Flowable Restorative A2 3M ESPE (FFR) (G3 o Flow) y se completó con el mismo volumen de composite de las del GI. Los resultados obtenidos fueron analizados por medio de ANOVA para mediciones repetidas. La media y la desviación estándar en kPa (tensión o estrés de contracción) registrado para cada grupo fueron: Grupo control: 126.2 (30.8); IV: 48.4(18); Flow: 27.9(19.5). El análisis estadístico mostró diferencias estadística mente significativas entre el grupo control y el resto (p=0.00), pero no hubo diferencias significativas entre la presencia de Ionómero vítreo o Composite Flow (IV y Flow). En las condiciones experimentales de este trabajo puede concluirse que la tensión de contracción generada durante la polimerización puede ser disminuida por la presencia de algún material interpuesto entre la preparación y el composite restaurador.


Subject(s)
Acrylic Resins , Silicon Dioxide , Composite Resins/chemistry , Dental Leakage , Dental Materials/chemistry , Dental Restoration, Permanent , Materials Testing , Dental Cavity Lining/methods , Dental Cavity Preparation , Polymerization , Glass Ionomer Cements/chemistry
5.
Rev. Asoc. Odontol. Argent ; 107(3): 79-81, jul.-sept. 2019.
Article in Spanish | LILACS | ID: biblio-1047872

ABSTRACT

Las convenciones internacionales relacionadas con las posibles consecuencias ambientales del empleo del mercurio a las que ha adherido la República Argentina llevan a la paulatina desaparición de la posibilidad del empleo de este elemento. Consecuentemente, se genera la necesidad de reducir y, en última instancia, eliminar el uso de productos médicos que lo contengan, como es el caso de la amalgama dental. Se requiere de la decisión conjunta de las comunidades académica y asistencial para definir estrategias a aplicar en la reducción gradual del uso de la amalgama dental. La forma de hacerlo y la tecnología para su reemplazo aún son inciertas (AU)


International conventions related to the possible environmental consequences of the use of mercury that the Argentine Republic has subscribed lead to the gradual disappearance of the possibility of using this element. Consequently, there is a need to reduce and ultimately eliminate the use of medical products that contain it, as is the case with dental amalgam. The joint decision of academic and healthcare communities is required to define strategies to be applied in the gradual reduction of the use of dental amalgam. The way to do it and the technology for its replacement still remain uncertain (AU)


Subject(s)
Environmental Health , Dental Amalgam/toxicity , Mercury/toxicity , Dental Restoration, Permanent
6.
Acta odontol. latinoam ; 30(1): 5-12, 2017. ilus, graf
Article in English | LILACS | ID: biblio-907401

ABSTRACT

The aim of this study was to determine the effect of SDF on thedentin­pulp complex using two models: teeth after SDFapplication (ex vivo) and experimental animal molars. Adescriptive study was performed using two models. In the firstmodel, primary teeth (ex vivo) with enamel­dentin caries, withoutpulp involvement and previously treated with 38% SDF, wereevaluated by means of two techniques: (a) Scanning ElectronMicroscopy (SEM) and energy­dispersive X­ray detector (EDS)to determine qualitative and quantitative composition, and (b)brightfield optical microscopy (OM) after decalcification. Thesecond model used laboratory animal molars from 12 maleWistar rats. Standardized enamel­dentin cavities approximately0.5 mm deep were made the distal fossa of the occlusal face ofboth first lower molars, to one of which a 38% SDF solution wasapplied, while the other was used as a control. Histologicalsections were prepared and dental pulp was evaluatedqualitatively in both groups. SEM on ex vivo teeth showed areasof hypermineralization in the intertubular dentin and few blockedtubules, while EDS detected Ag in the center of the lesion(7.34%), its concentration declining at the edges (1.71%), withnone in the areas farthest from the lesion...


El objetivo del trabajo fue determinar del efecto del DFP encomplejo dentino­pulpar aplicando dos modelos: piezasdentarias luego de su aplicación (ex vivo) y en molares deanimales experimentales. Se realizó un estudio descriptivoaplicando dos modelos: en piezas dentarias primarias (ex vivo)con caries amelodentinarias sin compromiso pulpar que hayansido sometidas previamente con DFP 38%, mediante dosevaluaciones: Microscopía electrónica de Barrido (MEB) ydetector de energía dispersiva de rayos X (EDS) a fin dedeterminar su composición cuali y cuantitativa y Microscopíaóptica de campo claro (MCC) mediante la técnica descalcifi ­cación y en molares de animales de laboratorio donde seutilizaron 12 ratas Wistar macho. La técnica fue estandarizadaen la fosa distal de la cara oclusal del primer molar inferior, serealizó una cavidad amelodentinaria aprox. 0.5 mm de profun ­didad, en ambos molares. En un molar se aplicó la soluciónDFP al 38 % y el opuesto como control. Se realizaron corteshistológicos y se evaluó en forma cualitativa la pulpa dentalen ambos grupos. En las piezas ex vivas mediante MEBse observaron áreas de hipermineralización en la dentinaintertubular y escasos conductillos obliterados y por EDS sedetectó Ag en el centro de la lesión (7.34%), disminuyendo suconcentración en los límites (1,71%) y no se detectó en las zonasmás alejadas de la misma. En MCC se observó DFP sellando losconductillos sólo en sitio de colocación y con una penetraciónlimitada, por debajo, los conductillos se observaron de aspectonormal y el tejido pulpar asociado con la caries tratadaha mostrado un infiltrado inflamatorio crónico y formaciónde dentina terciaria, sin observarse precipitado de Ag...


Subject(s)
Humans , Animals , Rats , Dental Pulp , Dentin , Dental Caries/therapy , Dental Pulp/ultrastructure , Diamines/therapeutic use , Molar , Silver Compounds/therapeutic use , Tooth, Deciduous , Decalcification Technique , Epidemiology, Descriptive , Histological Techniques , Microscopy, Electron, Scanning/methods
7.
Acta odontol. latinoam ; 28(1): 64-71, Apr. 2015. ilus, tab
Article in English | LILACS | ID: biblio-949691

ABSTRACT

The aim of this study was to determine the influence of the finishing protocol (FP) on flexural properties of several composites (CR). Twenty composite samples (25x2x2 mm) were prepared: G1 HelimolarR; G2 Filtek™ Z350;G3TetricR N Ceram, G4 Point 4™, G5 Premisa™; G6 Esthet.XR HD, G7 ice, G8 Vit-L-escenceR, G9 GrandioR, G10 TPHR3, G11 AmelogenR Plus, G12 Brilliant Enamel; G13 Filtek™ Z100 and randomly divided into four groups according to the finishing system: C control, J JiffyR, SS Super SnapR, AA AstropolR /AstrobrushR. Each sample was polished for 10 seconds with each sequence instrument, and stored in distilled water for 24 hours, after which a three-point flexure test was applied to determine flexural strength (FS) and modulus (Flexural modulus). Data were analyzed using a two-way multivariate ANOVA and means were compared with Tukey's test. Results were: FS level CR p=0.000 with significant differences. FS level FPp= 0.093 with significant differences. In order: FM level CR p 0.00 with significant differences. FM level PS p=0.001; with significant differences. Under the study conditions, the polishing systems based on silicone rubber decreased the flexural properties of composite resins.


El objetivo de este trabajo fue determinar la influencia del protocolo de pulido sobre las propiedades flexurales de varios composites. Se prepararon veinte probetas de composite (CR) (25x2x2 mm) en cada grupo: G1 HelimolarR; G2 Filtek™ Z350;G3TetricR N Ceram, G4 Point 4™, G5 Premisa™; G6 Esthet.XR HD, G7 ice, G8 Vit-L-escenceR, G9 GrandioR, G10 TPHR3, G11 AmelogenR Plus, G12 Brilliant Enamel; G13 Filtek™ Z100 y se dividieron aleatoriamente en cuatro grupos segun el sistema de pulido (SP) utilizado: C control, J JiffyR, SS Super SnapR, AA AstropolR /AstrobrushR. Cada probeta se pulio durante 10 segundos con cada secuencia de instrumentos, se almaceno en agua destilada durante 24 hs y se aplico un ensayo de resistencia flexural de tres puntos a fin de determinar la resistencia (RF) y el modulo (MF) flexural. Los valores obtenidos fueron analizados con un ANOVA multivariado de dos vias y comparacion de medias de Tukey. Los resultados obtenidos fueron: nivel de RF para CR p=0,000con diferencias significativas. RF nivel SP p= 0,093 con diferencias signi - ficativas. Para MF a nivel de CR p=0,000con diferencias signifi cativas. MF a nivel SP p=0,000, con diferencias signifi - cativas. En las condiciones de este trabajo se puede concluir que el uso de sistemas a base de gomas siliconadas disminuyen las propiedades flexurales de las resinas reforzadas restaura - doras. : composite resins; elastic modulus; dental polishing.


Subject(s)
Humans , Materials Testing , Surface Properties , Composite Resins , Dental Polishing
8.
Acta odontol. latinoam ; 28(3): 258-262, 2015. tab, ilus
Article in English | LILACS | ID: lil-781827

ABSTRACT

El objetivo de este estudio fue evaluar la estabilidad dimensional lineal de diferentes hidrocoloides irreversibles enfunción del tiempo. Se confeccionó una matriz metálica con sus correspondientes cubetas individuales realizadas con láminas termoplásticas (Sabilex, de 0.125 mm de espesor). Sele realizaron perforaciones para la retención del material. Se tomaron cinco impresiones con cada material a esta matriz, utilizando Kromopan 100 (LASCOD) [AlKr], que presentauna estabilidad dimensional de 100 horas, y Phase Plus (ZHERMACK) [AlPh], que tiene una estabilidad dimensional de 48 horas. Luego se tomaron fotografías estandarizadas adiferentes intervalos de tiempo (0, 15, 30, 45, 60, 120 minutos; 12, 24 y 96 horas), usando un dispositivo ad-hoc. Las imágenes se analizaron con software de procesamiento de imágenes(UTHSCSA Image Tool) realizando la medición de la distancia entre las intersecciones de surcos previamente realizados en la porción superior de la matriz. Los resultados obtenidos fueronanalizados mediante Análisis de Varianza para mediciones repetidas. Se detallan los datos iniciales y finales obtenidos (media y DS): AlKr: 16,44 (0,22) y 16,34 (0,11), AlPh: 16,40(0,06) y 16,18 (0,06). El análisis estadístico ha mostrado el efecto significativo para las variables material y tiempo. Bajo las condiciones de este estudio podemos concluir que tiempoafectaría significativamente la estabilidad dimensional lineal de los hidrocoloides irreversibles...


Subject(s)
Humans , Alginates/chemistry , Colloids/chemistry , Dimensional Measurement Accuracy , Dental Impression Materials/classification , Chemical Phenomena , Analysis of Variance , Materials Testing , Data Interpretation, Statistical , Time Factors
9.
Acta odontol. latinoam ; 28(2): 132-137, 2015. ilus, tab
Article in English | LILACS | ID: lil-768616

ABSTRACT

El objetivo del trabajo fue comparar la eficacia como sellador de dos ionómeros vítreos. Se emplearon 30 premolares sanos extraídos por razones ortodóncicas. Se dividieron en dos grupos iguales (n=15) .Grupo I: Fuji VII y Grupo II: Fuji IX. Los dientes, fueron conservados en saliva artificial (NAF) durante 10 días. Luego, fueron termociclados (250 ciclos) a 5ºC, 37ºC y60ºC. Posteriormente se sumergieron en violeta de genciana durante 24 hs. Una vez lavadas las muestras se seccionaron y evaluaron con el criterio de Williams y Winter, utilizando un microscopio óptico (Olympus BX-60M) para valorar la penetración del colorante. Los grados obtenidos para cada grupo fueron: en Grupo I (Fuji VII), Grado 1, 1 muestra y Grado3, 14 muestras (Media 2,87, Mediana 3 y SD 0.52). En el Grupo II (Fuji IX) los grados se distribuyeron así: Grado 0, 4 muestras, Grado 1, 3 muestras, Grado 2, 2 muestras y Grado 3, 6 muestras.(Media 1.67, Mediana 2 y SD 1.29). La Prueba exacta de Fisher (p=0,006) demostró diferencias estadísticamente significativa entre materiales. Se concluyó que el mejor sellado marginal fue obtenido utilizando el material Fuji IX comparado con Fuji VII cuando es utilizado como sellador.


The aim of this study was to evaluate in vitro the marginalmicroleakage of two glass ionomer materials used as pit andfissure sealants. Thirty healthy premolars extracted fororthodontic treatment were randomly assigned to two groups(n=15) and respectively sealed with two glass ionomers (Group I,Fuji VII and Group II, Fuji IX). All teeth were preserved inartificial saliva (NAF) for 10 days, thermocycled (250 cycles; 5ºC,37ºC and 60ºC), isolated, and immersed in 2% alcohol gentianviolet blue solution for 24 h. After washing, teeth were included inacrylic resin and sectioned longitudinally in a bucco-lingualdirection with a Struers-Minitom cutting device. Samples wereanalyzed for leakage using an optical microscope (Olympus BX-60M). TheWilliams and Winter semi-quantitative ranked scale wasused to score dye penetration. In Group I the grades weredistributed as follows: Grade 1, 1 sample and Grade 3, 14 samples(Mean 2.87 Median 3, SD 0.52). In Group II: Grade 0: 4 samples,Grade 1, 3 samples, Grade 2, 2 samples and Grade 3, 6 samples(Mean 1.67, Median 2, SD 1.29). Fisher’s exact test showedstatistically significant differences between materials (p=0.006).From these results, we conclude that Fuji IX had better marginalsealing than Fuji VII when used as a pit and fissure sealant.


Subject(s)
Humans , Glass Ionomer Cements/chemistry , Glass Ionomer Cements/therapeutic use , Dental Leakage/diagnosis , Pit and Fissure Sealants/therapeutic use , Bicuspid , In Vitro Techniques , Materials Testing , Data Interpretation, Statistical
10.
Acta odontol. latinoam ; 28(2): 192-198, 2015. ilus, tab
Article in English | LILACS | ID: lil-768625

ABSTRACT

El objetivo del presente trabajo fue analizar la ultraestructura y composición mineral de la superficie del esmalte de un molar con MIH, con y sin tratamiento de grabado ácido. Se analizaron una pieza dentaria permanente sin lesiones clínicas de MIH (controles) y una pieza con diagnóstico clínico de MIH leve y moderada, con indicación de extracción con y sin grabado acido (H3PO4 37 por ciento, 20”). Fueron procesadas para su observación con microscopio electrónico de barrido (SEM) ZEISS (Supra 40) y análisis de la composición mineral con detector EDS (Oxford Instruments). El esmalte del control mostró superficie prismática y patrón de grabado normales. El esmalte clínicamente sano en la pieza con MIH reveló una pérdida parcial del patrón prismático. La lesión leve se presentó porosa con ocasional esgrietas. La moderada presentó mayor porosidad, con grietas de mayor tamaño y presencia de gran cantidad de escamas. La composición mineral de las superficies afectadas mostró menor contenido de Ca y P y aumento de O y C. En la muestra con MIH, inclusive con aspecto normal, las desmineralizaciones no responden a un patrón de grabado, mostrando exposición de cristales con redondeamiento en los extremos de las varillas y menor desmineralización en los espacios interprismáticos. El grabado ácido incrementó la aparición de grietas y profundos poros en la estructura adamantina del esmalte con lesión. La composición mineral mostró en las lesiones moderadas una mayor disminución del contenido de Ca, P y Cl.El esmalte con MIH, inclusive en la superficie adamantina clínicamente intacta, presenta severas alteraciones ultraestructurales y cambios en la composición iónica afectando el patrónde grabado ácido, que podría interferir con los mecanismos de adhesión.


The aim of the present work was to analyze the ultrastructure and mineral composition of the surface of the enamel on amolar with MIH, with and without acid etching. A permanent tooth without clinical MIH lesions (control) and a tooth with clinical diagnosis of mild and moderate MIH, with indication for extraction, were processed with and without acid etching(H3PO437%, 20”) for observation with scanning electron microscope (SEM) ZEISS (Supra 40) and mineral composition analysis with an EDS detector (Oxford Instruments). The control enamel showed normal prismatic surface and etching pattern. The clinically health y enamel on the tooth with MIH revealed partial loss of prismatic pattern. The mild lesion wasporous with occasional cracks. The moderate lesion was moreporous, with larger cracks and many scales. The mineral composition of the affected surfaces had lower Ca and Pcontent and higher O and C. On the tooth with MIH, even on normal looking enamel, the demineralization does not correspond to an etching pattern, and exhibits exposure of crystals with rods with rounded ends and less demineralization in the inter-prismatic spaces. Acid etching increased the presence of cracks and deep pores in the adamantine structure of the enamel with lesion. In moderate lesions, the mineral composition had higher content of Ca, P and Cl. Enamel with MIH, even on clinically intact adamantine surfaces, shows severe alterations in the ultrastructure and changes in ionic composition, which affect the acid etching pattern and may interfere with adhesion.


Subject(s)
Humans , Child , Tooth Demineralization/diagnosis , Dental Enamel/ultrastructure , Acid Etching, Dental/methods , Molar/ultrastructure , Clinical Protocols , Dentition, Permanent , Schools, Dental , Photomicrography/methods , Microscopy, Electron, Scanning
11.
Rev. Asoc. Odontol. Argent ; 102(3): 99-100, sept. 2014.
Article in Spanish | LILACS | ID: lil-731424

ABSTRACT

La restauración del diente endodónticamente tratado ha sido estudiada desde todos los aspectos posibles, que incluyen consideraciones biológicas, biomecánicas ye stétias. Esto implica un profundo conocimiento de materiales y técnicas. Uno de los aspectos que se han evaluado de múltiples maneras es la adhesión de los sistemas de anclaje intrarradicular. La evaluación de la adhesión incluye ensayos mecánicos, infiriendo que cuanto más elevada sea, mejor va a ser su resistencia al asentamiento, endurecimiento y comportamiento clínico. Estos estudios suelen completarse con evaluaciones cualitativas, como observaciones microscópicas. Sin embargo, el diseño de este tipo de estudios presenta algunos desafíos. Esta editorial intenta presentar el tema desde su utilidad y dificultades


Subject(s)
Post and Core Technique , Dental Bonding/methods , Tooth, Nonvital , Biomechanical Phenomena , Evaluation Study , Tooth Fractures/prevention & control , Dental Materials/chemistry , Root Canal Therapy
12.
Acta odontol. latinoam ; 24(3): 289-294, 2011. ilus
Article in English | LILACS | ID: lil-668281

ABSTRACT

El objetivo del trabajo fue evaluar la estabilidad dimensional lineal de diferentes elastómeros para impresión. Se confeccionó una matriz metálica con sus correspondientes cubetas individuales realizadas con láminas termoplásticas (Marca Sabilex, de 0.125 mm de espesor). Se tomaron tres impresiones con cada material a estamatriz. Se utilizaron tres siliconas por adición: Examix-GC- (AdEx), Aquasil-Dentsply-(AdAq), y Panasil –Kettenbach-(AdPa); y tres siliconas por condensación: Densell-Dental Medrano-(CoDe), Speedex-Coltene-(CoSp), y Lastic-Kettenbach-(CoLa). Se realizaron todas las impresiones utilizando dos consistencias: pesada y liviana, con la técnica de un solo tiempo. Luego se tomaron fotografías estandarizadas a diferentes intervalos de tiempo (0, 15,30, 60, 120 minutos; 24 horas; 7 días y 14 días), con una cámara fotográfica digital, utilizando un dispositivo ad-hoc. Las imágenes se analizaron con software de procesamiento de imágenes (Image Tool) realizando la medición de la distancia entre las interseccionesde surcos previamente realizados en la porción superior de la matriz. Los resultados obtenidos fueron analizados mediante Análisis de varianza para mediciones repetidas. La media y el DSinicial y final para todos los materiales fue: AdEx: 1,32 (0,01) y 1,31 (0,00); AdAq: 1,32 (0,00) y 1,32 (0,00); AdPa: 1,327 (0,006) y 1,31 (0,00); CoDe: 1,32 (0,00) y 1,32 (0,01); CoSp: 1,327 (0,006) y 1,31 (0,00); CoLa: 1,327 (0,006) y 1,303 (0,006). La evaluaciónestadística mostró el efecto significativo de las variables material y tiempo. Conclusión: Bajo las condiciones de este estudio podemos concluir que el tiempo afectaría significativamente la estabilidad dimensional lineal de elastómeros para impresiones.


Subject(s)
Elastomers/chemistry , Dental Impression Materials/classification , Chemical Phenomena , Dental Impression Technique , Data Interpretation, Statistical , Time Factors
13.
Acta odontol. latinoam ; 23(1): 3-7, Apr. 2010. tab
Article in English | LILACS | ID: biblio-949628

ABSTRACT

The aim of this study was to evaluate the clinical behavior of two conventional glass ionomers used for pit and fissure sealing in terms of retention, marginal adaptation, caries recurrence and cracking. Eighty-three fully erupted first permanent molars were sealed, in a group of children aged 5 to 8 years. A doubleblind, single operator, paired design was used. Materials applied were Fuji IX and VII. Retention (R), presence of caries (PC), marginal discoloration (MD), marginal adaptation (MA) and cracking (C) were evaluated at 6 and 12 months using Ryge's criteria. Data registered 6 months after treatment were: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. Results after one year were: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. Statistical analysis using Fisher test showed no significant difference (p>0.05) for R, and MA. For PC, MD and C, values are not reported because both materials showed the same results. The second control showed no significant difference (p>0.05) for R, MA, PC, MD and C. Results suggest no difference between Fuji IX and Fuji VII as sealants in fully erupted permanent molars.


El objetivo de este trabajo fue evaluar el comportamiento clinico de dos ionomeros vitreos convencionales aplicados como selladores de fosas y fisuras. Se evaluo la retencion, decoloracion y adaptacion marginal, incidencia de caries y agrietamiento. Se sellaron ochenta y tres primeros molares totalmente erupcionados en un grupo de ninos de 5 a 8 anos. Se llevo a cabo un diseno de doble ciego, unico operador y apareado. Los materiales aplicados fueron Fuji IX y VII. Luego de 6 y 12 meses se recitaron los ninos y se evaluo: Retencion (R), presencia de caries (PC), decoloracion marginal (MD) y agrietamiento (C). La evaluacion se realizo utilizando los criterios de Ryge. Los datos registrados al cabo de 6 meses fueron: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. A los 12 meses: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. La evaluacion estadistica por medio de la prueba de Fisher no mostro diferencias significativas entre los materiales (p>0.05) para R y MA. En PC, MD y C, el valor de p no se indica ya que los resultados fueron identicos. El segundo control no mostro diferencias significativas (p>0.05) para R, MA, PC, MD y C. Los resultados sugieren que no existiria diferencia en la aplicacion de Fuji IX y Fuji VII como selladores de fosas y fisuras en molares totalmente erupcionados.


Subject(s)
Child , Child, Preschool , Humans , Pit and Fissure Sealants , Dental Fissures/therapy , Glass Ionomer Cements , Molar , Double-Blind Method
14.
Rev. Fac. Odontol. (B.Aires) ; 25(58): 17-20, 2010. ilus
Article in Spanish | LILACS | ID: lil-687494

ABSTRACT

El objetivo de esta revisión de la literatura es describir los procesos de alteración de la aparatología de uso en ortodoncia a partir de su interacción con el medio bucal. En este aspecto se describe el medio bucal desde el punto de vista químico-biológico y a partir de allí los mecanismos de corrosión y sus posibles efectos sobre los arcos y brackets. Este último aspecto es analizado desde su composición y configuración. Se realizan consideraciones también desde el punto de vista de los materiales sin uso y reciclados.


Subject(s)
Humans , Orthodontic Appliances/adverse effects , Corrosion , Orthodontic Brackets , Dental Alloys/chemistry , Conservation of Natural Resources , Metals/chemistry , Saliva/chemistry
15.
Rev. Asoc. Odontol. Argent ; 95(2): 139-142, abr.-mayo 2007. ilus, graf
Article in Spanish | LILACS | ID: lil-467754

ABSTRACT

El objetivo del presente estudio fue comparar in vitro la actividad antimicrobiana de dos cementos a base de trióxidos minerales agregados MTA Pro-Root Gray (Dentsply, Tulsa Dental, EE.UU.) y CPM (Cemento Portland Mejorado, Egeo, Argentina) en obturaciones retrógradas. Se utilizaron 32 dientes humanos unirradiculares extraídos y mantenidos en solución salina. El ápice fue resecado previa limpieza y conformación de los conductos. Se realizaron cavidades retrógradas de 3mm de profundidad que fueron obturadas con cada uno de los materiales. Las muestras se dividieron en dos grupos de doce dientes cada una y los ocho dientes restantes fueron considerados grupo control. Mediante curvas de sobrevivientes, a intervalos de 0,2, 4 y 24 horas se evaluó la actividad microbicida o inhibitoria frente a cuatro cepas de microoganismos. Los resultados obtenidos por curvas de desarrollo no mostraron diferencias estadísticamente significativas entre los grupos.


Subject(s)
Dental Cements/chemistry , In Vitro Techniques , Root Canal Filling Materials/chemistry , Retrograde Obturation/instrumentation , Bacteria, Anaerobic/classification , Bacteria, Anaerobic/growth & development , Cell Survival , Culture Media , Colony Count, Microbial/methods , Data Interpretation, Statistical
16.
Rev. Asoc. Odontol. Argent ; 94(2): 109-113, abr.-mayo 2006. ilus, tab
Article in Spanish | LILACS | ID: lil-431099

ABSTRACT

El objetivo de este estudio fue evaluar "in vivo" la exactitud en la determinación de la longitud de trabajo utilizando el localizador apical electrónico Root ZX. Los resultados fueron analizados estadísticamente con el método de frecuencias relativas y la prueba de chi cuadrado. La Fase I mostró diferencias estadísticamente significativas entre las mediciones aceptables y cortos y aceptables y pasados (p<0,05), no así entre las patologías. La Fase II mostró que no hubo diferencias estadísticamente significativas entre las mediciones aceptables y cortos y aceptables y pasados (p<0.05). Los resultados obtenidos en este estudio sugierenq ue las mediciones obtenidas dentro del rango prefijado en el Root ZX requieren un ajuste en la longitud obtenida clínicamente. De todos modos, las mediciones electrónicas con la ayuda de las interpretaciones radiográficas permiten mejorar la precisión en la obtención de una longitud de trabajo adecuada.


Subject(s)
Tooth Apex/anatomy & histology , Dental Instruments , Odontometry , Argentina , Dental Pulp Cavity , Electric Impedance/methods , Root Canal Therapy , Data Interpretation, Statistical
17.
Bol. Asoc. Argent. Odontol. Niños ; 35(1): 18-21, mar. 2006. ilus, tab
Article in Spanish | LILACS | ID: lil-427670

ABSTRACT

La adhesión consistente a dentina es de gran importancia en el éxito clínico de los tratamientos restauradores. Algunas de las maniobras utilizadas en los tratamientos odontológicos, involucran la aplicación de materiales con contenido de fenoles. Por eso, es importante evaluar si los materiales de obturación temporaria y elementos empleados en las pulpotomías pueden afectarla. El propósito de este informe es revisar las tendencias y conocimientos actuales respecto de la utilización de materiales y compuestos fenólicos en su relación con resinas reforzadas. En este trabajo se revisa la bibliografía publicada referente a la acción de los compuestos fenólicos sobre las resinas reforzadas en varios de sus aspectos: sus propiedades mecánicas, ópticas y su adhesión a estructuras dentarias. Conclusiones: la evidencia científica referida a la interacción entre compuestos fenólicos y composites es controversial, la decisión de utilización de materiales con contenido de fenoles sobre piezas dentarias que van a recibir un tratamiento restaurados/rehabilitador con composites, debería basarse en el tiempo durante el cual serán aplicados y para su utilización en plazos reducidos considerarse el empleo de materiales libres de fenoles


Subject(s)
Dental Bonding , Pulpotomy , Zinc Oxide-Eugenol Cement
18.
Rev. Asoc. Odontol. Argent ; 93(5): 443-446, oct.-dic. 2005. tab, graf
Article in Spanish | LILACS | ID: lil-420599

ABSTRACT

Se determinó el corrimiento de los siguientes selladores endodónticos: Endion-Voco (E), Endomethasone C-Septodont (EM), AH26-Denstply(AH), Bioseal Retard-Ogna (BR), Bioseal Normal-Ogna (BN), Detac Endo-Espe (KE), Procosol Satar Dental (P), Sealer26-Dentsply (S26), Diaket.-Espe (D) y TubliSeal-Kerr (TS), a temperatura y humedad ambiente y a 37ºC 95 por ciento de humedad relativa. Se prepararon 0,07 ml de mazcla de material y se colocaron sobre superficies de vidrio. Se inclinaron a 90º e inmediatamente se registró el desplazamiento producido en la masa del material. Se repitió la medición a los 15 y 60 minutos. Los valores máximos de corrimiento obtenidos para cada material fueron: E: 2.46; EM: 0.57; AH: 6.47; BR: 3.57; BN: 5.17; KE: 1.39; P: 0.79; S26: 1.03; D: 2.48; TS: 0.49. El corrimiento de los selladores endodónticos es afectado por el tiempo, las reacciones que producen su endurecimiento y por las condiciones ambientales


Subject(s)
Humidity , Chemical Phenomena , Data Interpretation, Statistical , Temperature
19.
Acta odontol. latinoam ; 18(2): 51-56, 2005. tab
Article in English | LILACS | ID: lil-427662

ABSTRACT

El objetivo de este trabajo fue evaluar "in vitro" la actividad antimicrobiana de conos antisépticos para obturación temporaria frente a microorganismos endodontopáticos. Fueron empleados conos con hidróxido de calcio (Roeko(R) e Hygienic (H)) con clorhexidina (Roeko) y conos de gutapercha como testigos. Los microorganismos estudiados fueron Streptococcus mutans (Sm), Enterococcus faecalis (Ef), Staphylococcus aureus Sta), Candida albicans (Ca) (ATCC 3153), Fusobacterium nucleatum (Fn)(ATCC 25586), Porphyromonas gingivalis (Pg)(ATCC 33277) y Prevotella intermedia (Pi)(ATCC 25611). La experiencia se dividió en tres etapas: 1º etapa: un cono de cada tipo se colocó sobre la superficie de placas de agar previamente sembradas con una suspensión homologada de cada microorganismo. 2º etapa: un cono de cada tipo fue sumergido prevo a su utilización en 2 ml de caldo durante 24 horas. Luego, se retiraron los conos y se los depositó sobre placas de agar previamente sembradas igual que en la 1º etapa. Todas las placas fueron incubadas de acuerdo a los requerimientos de oxígeno y tiempo de cada microorganismo. Los resultados se registraron a través de la extensión de los halos de inhibición microbiana observada. Se midió el pH de los caldos con tiras indicadoras de pH (Merck) rango 0-14, previo a la inmersión de los conos y después de retirarlos. 3º etapa: los caldos que contuvieron los conos se inocularon en suspensiones de los microorganismos en estudio, transcurrido el tiempo de incubación, 20 ul de los caldos se sembraron en cajas de Petri, se incubaron y se realizó el recuento de unidades formadoras de colonias (UFC). Resultados: los conos con clorhexidina presentaron halos de inhibición en la 1º etapa con todos los microorganismos probados y en la 2º etapa con Sm, Ef, Ca, Sta y Pg. Los conos con hidróxido de calcio, tanto Hygienic como Roeko, no produjeron halos de inhibición con ninguna de las cepas probadas. El pH de los caldos no se modificó. En el recuento de UFC los conos con clorhexidina produjeron inhibición total para todas las cepas. Se encontró efecto significativo para material (p<0.05)(ANOVA). Puede concluirse que bajo las condiciones del presente estudio, los conos que contienen clorhexidina son los más efectivos sobre los microorganismos probados


Subject(s)
Analysis of Variance , Candida albicans , Colony Count, Microbial , Culture Media , Enterococcus faecalis , Fusobacterium nucleatum , In Vitro Techniques , Porphyromonas gingivalis , Prevotella intermedia , Data Interpretation, Statistical , Streptococcus mutans
20.
Bol. Asoc. Argent. Odontol. Niños ; 29(2): 10-3, jun.-sept. 2000.
Article in Spanish | LILACS | ID: lil-278387

ABSTRACT

Una actualización sobre biomateriales debe partir de los factores de éxito clínico: diagnóstico-material-técnica. En el caso de materiales que van a ser usados en la clínica odontopediátrica, hay ciertos puntos que deben ser tenidos en cuenta, como las diferencias anátomo-histológicas del sustrato, el tiempo disponible para llevar a cabo el tratamiento de acuerdo con la edad del paciente, las diferencias funcionales y la duración esperada en la restauración. Para ello es importante el conocimiento de las características de cada tipo de material, esto permitirá utilizarlos con la técnica adecuada que permita obtener lo mejor de sus propiedades y así aprovechar sus ventajas al máximo posible. En este trabajo se describen los materiales de uso más habitual en odontopediatría: ionómeros vítreos (convencionales e híbridos), composites (micropartículas, híbridos, condensables, inteligentes), compómeros. En cada caso, se describen sus características, indicaciones, manipulación, y adhesión


Subject(s)
Humans , Child , Dental Care for Children/instrumentation , Biocompatible Materials/therapeutic use , Glass Ionomer Cements/therapeutic use , Compomers/therapeutic use , Composite Resins/therapeutic use , Dental Bonding , Fluorides/chemistry , Dental Restoration, Permanent/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL